889a96584ab63e1e7fae6040d440cb612b4a2a3d
2 Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
f61ec6b391 |
Read integrity, as-of context, and the shadow matchup resolve (A1-A7)
Seven orders of measurement-first repair. The served grade does not move. A0/A1 — the unordered page walk returned the right COUNT and the wrong ROWS: 410-617 of 2,490 duplicated with an equal number never returned, while rows.length matched the server exactly. safePaginate orders on a real unique key, verifies the tuple at runtime, and THROWS on a query error instead of treating it as end-of-data. Both hits PROVES are withdrawn: they were drawn through that reader, and defense_by_direction's distinct-n was likely below the gate floor all along. A2/A2b — rolled across every reader: 11 FAIL -> 0. Composite keys pulled from pg_index (the context tables are dated-composite and had no single unique column). The unordered helper is deleted, not parked. A3 — ledgerService and retentionService defaulted the SAME env var to DIFFERENT versions, so no ledger row ever carried the marker eligibility requires. One source now. model_snapshots settlement moved onto the cron: 15,484 -> 28,894 settled, repaired-champion 0 -> 7,556. A4 — hitsFactorContext takes an as-of cutoff. Refusal over reconstruction: no row at-or-before the date means the factor does not apply, never the nearest row. Live path unchanged, proven 400/400 on real rows. A5 — factor_inputs freezes what the factor READ, never the multiplier, so an audit can recompute and check. It also recorded the finding: the three hits factors have NEVER fired. prop.opponent and prop.opposing_pitcher are read by the resolver and written by nothing. A6/A7 — matchupKeys resolves those keys from the posted lineup plus the schedule's probable pitchers, and fires the factors into a SHADOW freeze: 248 fires on 308 props, 245 of which would move the grade. The served forecast is untouched. specs/a8-shadow-factor-gate.md pre-registers the test that decides whether they ever go live. Nothing is turned on. CALIBRATION_DEPLOYED stays []. Both verdicts stay withdrawn. 4,772 tests / 371 suites green, web build exit 0, read-integrity harness 34/34. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com> |
||
|
|
43f65d30cb |
Wire the three proven hits factors pre-grade: transmission proven, gain
inconclusive THE BUG THIS NEARLY SHIPPED AS A FINDING. The first audit reported 0 factors fired on all 1,140 rows. Not a result -- my paging helper ordered by `id`, and batter_spray, team_defense, platoon_splits and statcast_aggregates have composite primary keys with NO id column. The query errored, the loop broke on error, and four fully-populated tables read as empty. hitsFactorContext.js -- the PRODUCTION loader -- had the identical defect, so live wiring would have loaded nothing and served unadjusted while logging success. Third occurrence of this class in one session. Both loaders now order by a real column and THROW rather than degrade. The Phase 2 gate is what caught it: no resolution number was quoted until transmission was proved. PHASE 1 — pipeline is now base -> FACTORS -> CALIBRATE -> GRADE. Context built in snapshotService BEFORE gradeAndCacheSlate (was line 640+, grade at 454), threaded per prop, applied to p_over before p_win is set with p_win_prefactor and a full trace retained. Hits only. Coverage 859/1140 rows (75%): 474 with all three factors, 256 two, 129 one, 281 none. PHASE 2 — TRANSMISSION PROVEN, 12/12 sign-correct, 4/4 per factor, each applied IN ISOLATION. My first table compared each factor's expected sign against the COMPOSITE change and showed 3 false failures -- with three factors firing the net can oppose any single member; that was a flaw in the test, not the wiring. Two under-side rows confirm the flip is handled: a factor raising p(over) correctly lowers p_win. Switch hitters (Bailey, Bell, Rocchio) took no spray adjustment while their other factors fired normally -- the refusal is selective, not a blanket skip. PHASE 3/4 — both maps refit on the factor-adjusted forecast; the shadow-duel baseline is VOID and restarts, since it accumulated against a different forecast. Point-in-time, 765 held-out rows: reliability 0.00795 -> 0.00828 RESOLUTION 0.00229 -> 0.00345 (variance explained 0.93% -> 1.39%) Brier 0.25398 -> 0.25305 delta -0.00093 CI [-0.00225,+0.00002] Resolution rose 51% relative. The CI TOUCHES ZERO on 4 eval dates, so the composition does NOT earn a proven keep -- three isolated passes did not grant a composed pass. INCONCLUSIVE, reported as such. The gain is far below the sum of the isolated effects, which is expected: all three run through the same pitcher-batter confrontation and share signal. PHASE 5 — 1.39% of variance is still far below what band separation needs. The pivot was correct and incomplete: the plumbing defect was real and is fixed, three proven factors reach the served number for the first time, and transmission alone did not buy grade separation. Next arc is factor STRENGTH and BREADTH, not more plumbing. PHASE 6 — rbi anomaly logged, not chased: 14.51% variance explained vs hits 1.03%, on the stat we do not serve corrected and which has no proven factors. Either the biggest lever on the board or a mirage; it deserves its own order. The byte-identical invariant INVERTED for hits by design. All 13 frozen non-hits modules verified unchanged, probabilityEstimator included -- the factors ride outside it. No new Bonferroni slot; the composed OOS claim is reported with its CI and not claimed as a pass. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01W1sivYNqY2TS5ftykmHBU9 |